DPA 500N
Digital Power analyzer for harmonics & flicker testing
Highlights
• Full-compliant acc. to JIS 61000-3-2 (Japanese standard)
• Edition 3 compliant for Class A
• Class X for special measurements
• Variable limit values
• Real-time data acquisition
• Internal hard disk for data storage
• Separate input for voltage and current
• Wide-range current input
• Built-in lumped flicker impedance
• USB interface for control and data transfer
• Control and analyzing software for Windows Vista and Windows 7
• Optional dpa.control software
•
DPA 500N Datasheet
|
Application
Harmonics and interharmonics are caused by modern electronic power conditioning
modules. Such, mostly non-linear, modules to control loads and to reduce power consumption
is the source of voltage at unwanted frequencies superposed on the supply voltage.
Voltage fluctuations caused by varying load currents may influence the luminance
or the spectral distribution of lighting systems. The impression of the unsteadiness
of visual sensation induced by this light stimulus is called flicker.
The DPA500N harmonics and flicker analyzer is used for single phase applications.
Benefits
The fully compliant harmonics and flicker analyzer
The DPA 500N is a fully compliant analyzer for harmonics and flicker as per the
latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 requirements. It follows
the design specifications as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class
A instruments) and IEC/EN 61000-4-15:2003.
Based on a real-time kernel and equipped with its own harddisk it allows to record
the measuring data continuously without any gaps or overlapping. The rectangular
measurement window is synchronized to each group of 10 or 12 cycles of the mains
supply frequency (50Hz or 60Hz) by means of a digital PLL (Phase Lock Loop). A wide-range
current input (up to 50A) avoids loss of measured data due to range switching that
would occur when using different shunt resistors.
The classification of the measurement can be selected at any time, before or after
the measurement has been performed. During all measurements the AC supply voltage
is measured simultaneously with the current.
The built-in flicker impedance, which is automatically selected when doing flicker
measurement, makes the
DPA 500N a complete single-box unit for both harmonics and flicker analysis.
By means of an external current clamp (optional) the current range can be extended
up to 140Arms and more.
Standards
| EN 301489-1 |
EN 61000-3-3 |
IEC 60601-1-2 |
IEC 61000-4-15 |
| EN 301489-17 |
EN 61000-4-15 |
IEC 61000-3-11 |
IEC 61000-4-7 |
| EN 301489-24 |
EN 61000-4-7 |
IEC 61000-3-12 |
IEC 61326 |
| EN 301489-7 |
EN 61000-6-1 |
IEC 61000-3-2 |
JIS C 61000-3-2 |
| EN 61000-3-2 |
EN 61000-6-2 |
IEC 61000-3-3 |
|

|
DPA 503N
3-Phase Digital Power analyzer for harmonics & flicker testing
Highlights
• Full-compliant analyzer
• Real-time data acquisition
• Internal hard disk for data storage
• 6 input channels
• Separate inputs for voltage and current
• Wide-range current input up to 140Arms
• 16bit A/D converter
• Self-calibration function
• Optional dpa.control software
•
DPA 503N Datasheet
|
Application
Harmonics and interharmonics are caused by modern electronic power conditioning
modules. Such, mostly non-linear, modules to control loads and to reduce power consumption
is the source of voltage at unwanted frequencies superposed on the supply voltage.
Voltage fluctuations caused by varying load currents may influence the luminance
or the spectral distribution of lighting systems. The impression of the unsteadiness
of visual sensation induced by this light stimulus is called flicker.
The DPA 503N is used for 3-phase applications but also supports single phase applications.
Benefits
The fully compliant harmonics and flicker analyzer
The DPA 503N is a fully compliant analyzer for harmonics and flicker as per the
latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 as well as IEC/EN
61000-3-11 and IEC/EN 61000-3-12 requirements. The DPA 503N has six independent
input channels; three for voltage and three for current. It follows the design specifications
as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class A instruments) for harmonics
analyzers and IEC/EN 61000-4-15:2003 for flicker meters.
Based on a real-time kernel and equipped with its own harddisk it allows to record
the measuring data continuously without any gaps or overlapping. The rectangular
measurement window is synchronised to each group of 10 or 12 cycles of the mains
supply frequency (50Hz or 60Hz) by means of a digital PLL (Phase Lock Loop). A wide-range
current input (up to 140A) avoids loss of measured data due to range switching that
would occur when using different shunt resistors.
The classification of the measurement can be selected at any time, before or after
the measurement has been performed. During all measurements the AC supply voltage
is measured simultaneously with the current
Standards
| EN 301489-1 |
EN 61000-3-2 |
IEC 60601-1-2 |
IEC 61000-4-7 |
| EN 301489-17 |
EN 61000-3-3 |
IEC 61000-3-11 |
IEC 61326 |
| EN 301489-24 |
EN 61000-4-15 |
IEC 61000-3-12 |
JIS C 61000-3-2 |
| EN 301489-7 |
EN 61000-4-7 |
IEC 61000-3-2 |
|
| EN 61000-3-11 |
EN 61000-6-1 |
IEC 61000-3-3 |
|
| EN 61000-3-12 |
EN 61000-6-2 |
IEC 61000-4-15 |
|

|
ACS 500N6
Single phase AC voltage source 6 kVA
Highlights
• Frequency (fund.) 10Hz .. 80Hz
• Output power max. 6,000VA
• Output voltage max. 300V
• Inrush current capability
• Remote control via RS232
•
ACS 500N6 Datasheet
|
Application
ACS 500N6 is a single phase AC source, specifically designed for harmonics and flicker
testing. It meets the corresponding specifications as per EN/IEC 61000-3-2 and EN/IEC
61000-3-3 as well as JIS C 61000-3-2.
ACS 500N6 provides the perfect sinusoidal and stable voltage signal specified to
perform fully compliant harmonics and flicker measurements/analysis despite of the
mains supply frequency and steadyness of the voltage.
Benefits
Sinusoidal Voltage for Harmonics and Flicker Measurements
As per standard requirements a pure voltage is needed for measurements of harmonics
and flicker. The output voltage of the ACS 500N6 is guaranteed to be sinusoidal
with a very low distortion (THD) of less than 0.1% regardless of the load. Furthermore
the voltage is kept stable within 0.1% independent of the load, even if the load
is variable.
No matter what the condition of the mains supply might be ACS 500N6 fulfills the
high standard for purety and stability of both the sinuoidal voltage signal and
the frequency. With a power of 6kVA it is well dimensioned for measurements as per
EN/IEC 61000-3-2 and EN/IEC 61000-3-3 as well as JIS C 61000-3-2 up to 16A.
The ACS 500N6 is electronically protected against overtemperature, overcurrent,
overvoltage and undervoltage.
Used with an EM TEST DPA 500 Series harmonics and flicker analyzer ACS 500N6 is
fully remote controlled by dpa.control software via RS232 interface.
Standards
| EN 61000-3-2 |
| EN 61000-3-3 |
| IEC 61000-3-2 |
| IEC 61000-3-3 |
| JIS C 61000-3-2 |

|
ACS 500N3
Single phase AC voltage source 3 kVA
Highlights
• Frequency (fund.) 10Hz .. 80Hz
• Very low distortion (THD)
• Very high voltage stability
• Output power max. 3,000VA
• Output voltage max. 300V
• High overcurrent capability
• Inrush current capability
• Remote controlled by the DPA 500N via RS232
•
ACS 500N3 Datasheet
|
Application
ACS 500N3 is a single phase AC source, specifically designed for harmonics and flicker
testing. It meets the corresponding specifications as per EN/IEC 61000-3-2 and EN/IEC
61000-3-3 as well as JIS C 61000-3-2.
ACS 500N3 provides the perfect sinusoidal and stable voltage signal specified to
perform fully compliant harmonics and flicker analysis despite of the mains supply
frequency and steadyness of the voltage.
Benefits
Sinusoidal Voltage for Harmonics and Flicker Measurements
As per standard requirements a pure voltage is needed for measurements of harmonics
and flicker. The output voltage of the ACS 500N3 is guaranteed to be sinusoidal
with a very low distortion (THD) of less than 0.1% regardless of the load. Furthermore
the voltage is kept stable within 0.1% independent of the load, even if the load
is variable.
No matter what the condition of the mains supply might be ACS 500N3 fulfills the
high standard for purety and stability of both the sinuoidal voltage signal and
the frequency. With its power of 3,000VA it can be used for measurements as per
EN/IEC 61000-3-2 and EN/IEC 61000-3-3 as well as JIS C 61000-3-2 on DUTs with small
power consumption, not exceeding 10A of nominal current for resistive load.
The ACS 500N3 AC voltage source is electronically protected against overtemperature,
overcurrent, overvoltage and undervoltage.
Used with EM TEST DPA 500 Series harmonics and flicker analyzers ACS 500N3 is fully
remote controlled by dpa.control software via RS232 interface.
Standards
| EN 61000-3-2 |
| EN 61000-3-3 |
| IEC 61000-3-2 |
| IEC 61000-3-3 |
| JIS C 61000-3-2 |

|
ACS 500N2.2
Single Phase AC Voltage Source 2 kVA, galvanically isolated
Highlights
• Frequency (fund.) 10Hz .. 80Hz
• Very low distortion (THD)
• Very high voltage stability
• Output power max. 2,000VA
• Output voltage max. 330V
• High overcurrent capability
• Inrush current capability
• Remote controlled by CWS 500N4 via RS232
• Optional icd.control software
•
CWS 500N3 Datasheet
|
Application
ACS 500N2.2 is a single phase AC source, specifically designed for test applications
as per IEC 61000-4-16 in combination with the CWS 500N4 common-mode disturbance
simulator. It also meets the requirements fo IEC/EN 61000-3-2 and IEC/EN 61000-3-3.
The galvanically isolated input guarantees the test signal to be separated from
the mains supply voltage.
By means of the ACS 500N2.2 the capabilities of the CWS 500N4 can be expanded for
tests at 16.66Hz as well as 50Hz and 60Hz independent from the actual mains supply
frequency delivering a max. output voltage of 330V.
Standards
| EN 61000-3-2 |
IEC 61000-3-2 |
IEC 61543 |
| EN 61000-3-3 |
IEC 61000-3-3 |
IEC 61850-3 |
| EN 61000-4-16 |
IEC 61000-4-16 |
|
| IEC 60533 |
IEC 61326 |
|

|
AIF 503N-series
Three-Phase flicker impedances up to 75A
Highlights
• Impedances values as per IEC/EN 61000-3-3 & IEC/EN 61000-3-11
• Non-saturable air coil inductors
• Line voltage 3 x 400V
• Line current up to 75A per phase (depending on model)
• Automatic overcurrent protection
• Status indication by LED
• Remote-controlled by DPA 503N
•
AIF 503N-series Datasheet
|
Application
The AIF 503N-series are three-phase flicker impedances with a nominal current from
16A up to 75A per phase offering two different impedance values. Zref is used as
the flicker impedance as per IEC/EN 61000-3-3 and specified by IEC 60725. Ztest
is used for equipment being intended for connection to a public low-voltage distribution
system having a service current supply capability of more than 100A specified in
IEC/EN 61000-3-11.
Benefits
Three-phase Flicker Impedance for Measurements up to 75A
The AIF 503N-series unifies the required impedance values for two applications (except
for the AIF 503N16 model). It offers a flicker impedance with the values in accordance
with IEC 60725 for flicker measurements as per IEC/EN 61000-3-3. It also includes
a second impedance used for flicker measurements on DUTs with a rated current above
16A which are intended to be connected to a public low-voltage distribution system
with a service current of more than 100A.
The inductors used are non-saturable air coils and are manually matched to the specified
value.
The AIF 503N-series is used along with the DPA503N for single phase as well as for
three phase measurements. The AIF 503N-series is fully remote controlled by dpa.control
software. LED indicators on the front panel show the actual mode of use. The AIF
503N32/-N63/-N75 are delivered in a rack on wheels there is space to house the DPA503N
for best user convenience.
Standards
| EN 61000-3-11 |
IEC 61000-3-11 |
| EN 61000-3-3 |
IEC 61000-3-3 |
| IEC 60725 |