Lionheart Northwest RF Microwave Equipment, EMC Test Equipment RF/Microwave, EMC and
Test & Measurement Solutions
for the Pacific Northwest
Phone
Fax
Email
(425) 882-2587
(425) 952-8739
sales@lionheartnw.com
Coupling Networks for EMC Testing

EM TEST offers a large variety of coupling/decoupling networks for different test applications for single phase and three-phase mains supplies as well as for signal/data lines and telecommunication lines. Apart from the standard coupling/decoupling networks EM TEST also provides special solutions for higher supply voltages (e.g. 3x690VAC or up to 1,000V DC) and higher currents (up to 100A and more) or for higher surge voltages up to 12kV.

coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test

CDN's

Coupling / decoupling networks according to IEC/EN 61000-4-6 and CISPR 15


Highlights

• M-type CDN's for supply lines available up to 75A
• S-type CDN's for shielded lines and different types of connectors (BNC, USB, SubD etc.)
• T-type CDN's for telecom lines
• AF-type CDN's for unbalanced lines
• Calibration certificat included
• Calibration accessories and adapters depending on type of CDN
• Special CDN\'s on request

CDN Datasheet

Application

Coupling/decoupling networks for conducted immunity testing

Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and CISPR 15 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines. A vast range of appropriate coupling/decoupling networks as well as the necessary accessories for standard compliant levelling are avialable.

You'll find an overview of all available CDN's on the datasheet. Apart from the listed standard coupling/decoupling networks EM TEST also supply special or customised coupling/decoupling networks.

Quality by LÜTHI

All EM TEST CDN's are manufactured by Lüthi

The Lüthi AG, headquartered in Frenkendorf, Switzerland, is one of the world's leading and best known manufacturers of coupling/decoupling networks for conducted immunity testing and emission measurement as well as of EMC measuring clamps and accessories.

In January 2010 the Lüthi AG became a part of the EM TEST Group. It will be independently operated and the Lüthi brand will remain. As one of the pioneers in the development of EMC measurement clamps, Lüthi AG products are chosen by the most important suppliers of EMC measuring systems world-wide.

Standards

CISPR 15 EN 61000-4-6 IEC 61000-4-6
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test, ANSI/IEEE C62.41

CNI 501x-series

Combined 1-phase coupling/decoupling networks for Burst and Surge testing up to 10kV


Highlights

• Combined coupler for EFT/Burst and Surge testing
• Surge as per ANSI/IEEE C62.41 (models CNI 501Bx only, other couplers on request)
• LEDs indicate active mode and coupling
• Automatic selection of Surge impedance
• Fully remote controlled by EM TEST generators
• Meet requirements up to 1,000V DC

CNI 501x-series Datasheet

Application

1-phase Coupling/decoupling networks for EFT/burst and Surge

The single phase coupling/decoupling networks of the CNI 501x-series are used to couple EFT/Burst pulses and Surge pulses on to AC and/or DC supply lines.

Within the range of EM TEST coupling/decoupling networks we offer different models for test voltages from 5kV up to 10kV with DUT currents of 16A, 32A, 63A and 100A (higher current ratings on request) for the various test requirements and equipment configuration.

Benefits

All EM TEST CDN's are manufactured by Lüthi

The CNI 501x-series coupling/decoupling networks are built fully complying to the standard requirements of EN/IEC 61000-4-4 and EN/IEC 61000-4-5. Residual voltage levels are carefully considered as well as the value of the decoupling inductors in order to meet the requirements with regard to voltage drop at the rated current of each type of CDN. Apart from the coverage of the EN/IEC 61000-4-5 standard the CNI 501Bx series also fully complies with the surge test requirements outlined in ANSI/IEEE C62.41.

Being fully controlled by the related generators couplings of the CNI 501x-series are set automatically as selected for the test (either by manual operation or via software). When performing surge tests the generators will automatically set the required source impedance depending on the standard and the coupling mode.

Standards

ANSI/IEEE C62.41 EN 61000-6-1 IEC 61000-4-12 IEC 61009-1 ITU-T K.21
EN 61000-4-12 EN 61000-6-2 IEC 61000-4-4 IEC 61326 ITU-T K.45
EN 61000-4-4 EN 61543 IEC 61000-4-5 IEC 61850-3  
EN 61000-4-5 IEC 60601-1-2 IEC 61008-1 ITU-T K.20  
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test, ANSI/IEEE C62.41

CNI 503x-series

Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV


Highlights

• Combined coupler for EFT/Burst and Surge
• Surge as per ANSI/IEEE C62.41 (models CNI 503Bx only, other couplers on request)
• LEDs indicate active mode and coupling
• Automatic selection of Surge impedance
• Fully remote controlled by EM TEST generators
• Meet requirements for 3x690VAC and 1,000VDC

CNI 503x-series Datasheet

Application

Coupling/decoupling networks for EFT/burst and Surge

The three-phase coupling/decoupling networks of the CNI 503x series are used to couple EFT/Burst pulses and Surge pulses on DC-lines or to three-phase (4-wire or 5-wire supply lines) mains supply systems for voltages up to 1,000VDC / 3x690VAC. This includes the more and more common testing of inverters used in the area of renewable energies (e.g. photovoltaic systems, wind power stations, electric cars).

Within the range of EM TEST coupling/decoupling networks we offer different models for test voltages from 5kV up to 10kV with DUT currents of 16A, 32A, 63A and 100A (higher current ratings on request) for the various test requirements and equipment configuration.

Benefits

The CNI 503x-series coupling/decoupling networks are built fully complying to the standard requirements of EN/IEC 61000-4-4 and EN/IEC 61000-4-5. Residual voltage levels are carefully considered as well as the value of the decoupling inductors in order to meet the requirements with regard to voltage drop at the rated current of each type of CDN. Apart from the coverage of the EN/IEC 61000-4-5 standard the CNI 503Bx series also fully complies with the surge test requirements outlined in ANSI/IEEE C62.41.

Being fully controlled by the related generators couplings of the CNI 503x are set automatically as selected for the test (either by manual operation or via software). When performing surge tests the generators will automatically set the required source impedance depending on the standard and the coupling mode.

Standards

ANSI/IEEE C62.41 EN 61000-6-1 IEC 61000-4-12 IEC 61009-1 ITU-T K.21
EN 61000-4-12 EN 61000-6-2 IEC 61000-4-4 IEC 61326 ITU-T K.45
EN 61000-4-4 EN 61543 IEC 61000-4-5 IEC 61850-3  
EN 61000-4-5 IEC 60601-1-2 IEC 61008-1 ITU-T K.20  
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test

CNI 508N1

Coupling / Decoupling network for shielded high-speed communication lines up to 1GBit/s


Highlights

• Surge test voltage up to 4kV (1.2/50us)
• Ringwave test voltage up to 4kV (0.5us/100kHz)
• Burst test voltage up to 4kV (5/50ns)
• Residual voltage max. 15V at 2kV
• Coupling to shielded lines with up to 4 pairs
• Data transfer up to 1,000MBit/s
• Fully compatible to PoE and PoE+ requirements
• DUT/AE connection via RJ45 male connectors

CNI 508N1 Datasheet

Application

CNI 508N1 - The unique coupling/decoupling network for shielded high-speed communication lines

The EM TEST CNI 508N1 is the first coupling/decoupling network available on the market to couple Surge, Ringwave and EFT/Burst pulses onto shielded high-speed communication lines with data rates up to 1,000MBit/s in a single unit.

The CNI 508N1 can be used for test voltages of up to 4kV. For tests using the 1.2/50us surge the CNI 508N1 is based on IEC 61000-4-5(2005).

Additionally, it fully supports PoE and PoE+ standard requirements as per IEEE 802.3af-2003 and IEEE 802.3at-2009.

Benefits

CNI 508N1 - Single box for Surge/Ringwave/Burst coupling onto shielded high-speed communication lines

The EM TEST CNI 508N1 is a specifically designed and approved coupling/decoupling network for tests of shielded high-speed communication lines.

By means of the CNI 508N1 Surge pulses (1.2/50us) as per IEC/EN 61000-4-5, Ringwave (0.5us/100kHz) as per IEC/EN 61000-4-12 and EFT/Burst pulses (5/50ns as per IEC/EN 61000-4-4) can be coupled. A maximum test voltage of 4kV can be applied to the lines under test.

Its unique design allows data rates of up to 1,000MBit/s to be transmitted without degradation by the coupling/decoupling network. The CNI 508N1 complies to PoE requirements as per IEEE 802.3af-2003 as well to P0E+ (PoE plus) requirements as per IEEE 802.3at-2009 with a current of up to 600mA and a power of up to 25.5W.

The integrated decoupling network protects the auxiliary equipment limiting the residual voltage to max. 15V at 2kV test voltage. The CNI 508N1 is fitted with female RJ45 connectors to connect telecommunication devices.

Standards

EN 61000-4-12 EN 61000-6-2
EN 61000-4-4 IEC 61000-4-12
EN 61000-4-5 IEC 61000-4-4
EN 61000-6-1 IEC 61000-4-5
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test

CNV 508N4

Coupling/decoupling networks for 4 pairs/8 lines as per IEC 60255-22-1


Highlights

• Selection of all coupling modes as per IEC 60255-22-1
• Remote controlled by the OCS 500N6
• Coupling capacitor 0.5uF
• Decoupling inductor >1.5mH per line
• Nominal line voltage max. 250V AC/DC
• Nominal line current 4A AC/DC or 16A AC/DC

CNV 508N4-series Datasheet

Application

Coupling/Decoupling networks for testing measuring relays and protection equipment

The CNV 508N4 series are special coupling/decoupling networks being used to perform "Electrical disturbance tests for measuring relays and protection equipment" in accordance to IEC 60255-22-1. A capacitance of 0.5uF is specified to couple the pulses on to the lines.

Each line has a decoupling inductor of >1.5mH to protect the auxiliary equipment from being subjected to the test pulse. The disturbance signal used for this test is a damped oscillatory pulse with a frequency of 1MHz, generated by the EM TEST OCS 500N6.

Benefits

Fully-automatic coupling networks for IEC 60255-22-1

Depending on the configuration of the DUT several different test set-up's are used to perform tests in differential mode (line-to-line of the same pair) or common mode (each pair to ground or one pair to all other pairs with these being grounded). The CNV 508N4 is automatically set by the OCS 500N6 selecting the desired coupling mode and lines to be coupled. The coupler offers capability to test up to 4 pairs/8 lines.

The test of measuring relays and protection equipment as outlined in IEC 60255-22-1 includes different coupling modes to test the DUT under different conditions. Each pair of lines is tested individually in differential mode. Common mode test is applied to each pair to ground and to each pair with the other pairs connected to ground.

The EM TEST CNV 508N4 series are a dedicated CDNs for these applications, fully automatic, remote controlled by the OCS 500N6 for the various coupling modes. This offers best user convenience and reliability that all couplings required are tested sequently. The selected coupling mode and lines actually being tested are indicated by LEDs.

Standards

IEC 60255-22-1
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test

CNV 504N/508N series

Coupling/decoupling networks for unshielded unsymmetrical interconnection lines


Highlights

• CDN as per IEC/EN 61000-4-5 and IEC/EN 61000-4-12
• Coupling via gas arrestor or 0.5 µF capacitor for Surge (3.3µF capacitor for Ringwave)
• 20mH decoupling inductor per line
• Differential mode or Common mode coupling selectable
• Test voltage up to 4kV, 7kV and 10kV
• Line voltage 50V (higher voltages on request)
• Line current 1A (higher current values on request)

CNV 5084N/508N series Datasheet

Application

CNV 504N/508N - Coupling decoupling networks for signal/data lines

Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnection lines (signal/data lines) by means of standalone coupling/decoupling networks. For such testing EM TEST offers a range of CNVs for either 4 or 8 signal/data lines.

According to EN/IEC 61000-4-5 resp. EN/IEC 61000-4-12 the pulses are coupled via different coupling elements such as capacitors, gas arrestors or diodes depending on the characteristics of the line signals.

Benefits

CNV 504N/508N series - Multifunctional coupling/decoupling networks

The EM TEST CNV 504N/508N series of coupling decoupling networks are multifunctional CNVs for the application of Surge and Ringwave pulses onto signal/data lines.

The standard CNV 504N/508N models combine three different applications; coupling of Surge pulse via capacitor or gas arrestor and coupling of Ringwave pulses via capacitor being required by the relevant standards. The required coupling mode can easily be selected by means of a simple jumper.

The CNVs also include the required decoupling part consisting of decoupling inductors of 20mH for each line. To protect the auxiliary equipment being needed for testing the DUT an additional protection circuit is integrated at the signal/data line input.

EM TEST offers CNV 504N/CNV 508N coupling/decoupling networks for various test voltages up to 10kV and for higher signal voltages/currents (up to 600V and up to 4A). Dedicated CNVs are available e.g. for railway applications as per EN 50155 and for other customer specific test applications.

Standards

EN 50121 EN 61000-4-12 IEC 61000-4-12 IEC 61326
EN 50155 EN 61000-4-5 IEC 61000-4-5  
coupling network, decoupling network, coupling decoupling network, ringwave test, surge test, burst test

CNV 504N5 series

Coupling/decoupling networks for 4 signal/data lines


Highlights

• Dedicated CDN for the coupling of damped oscillatory waves as per EN/IEC 61000-4-18
• Coupling capacitor 0.5uF
• Decoupling inductor 1.5mH per line
• Nominal line voltage 50V or 250V AC/DC
• Nominal line current 4A AC/DC

CNV 504N5 series Datasheet

Application

Coupling/Decoupling networks for testing measuring relays and protection equipment

The CNV 504N5-series coupling/decoupling networks are used to apply damped oscillatory waves onto signal/data lines in accordance to EN/IEC 61000-4-18. A capacitance of 0.5uF is specified to couple the pulses on to the lines. Each line has a decoupling inductor of 1.5mH to protect the auxiliary equipment from being subjected to the test pulse. The disturbance signal used for this test is a damped oscillatory pulse with a frequency of 100kHz or 1MHz, being generated by the EM TEST OCS 500M6.

The CNV 504N5 series supports voltages of up to 250V AC/DC and a current of up to 4A AC/DC.

Standards

EN 61000-4-18 IEC 61000-4-18