EFT 500N5-series
Electrical Fast Transient Generator
Highlights
• 10,000 pulses/sec.
• 4.8kV Burst voltage
• Spike frequency up to 1MHz
• Built-in 1ph or 3ph coupler up to 50A
• Pulse verification acc. to Ed.2 on each coupling path
• Standard test routines
• USB and GPIB interfaces
• Software for Windows Vista & Windows 7
• Optional iec.control software
•
EFT 500N5-series Datasheet
|
Application
EFT 500N5 - EFT/Burst tester
The EFT 500N5 is the state-of-the-art EFT/Burst tester with a built-in coupling/decoupling
network for single phase or three-phase mains supply lines and a HV terminal to
connect a capacitive coupling clamp.
The spike frequency can be varied from as low as 100Hz up to 1,000kHz. The EFT 500N5
is capable to generate 10,000 spikes per second or up to 1,000 spikes per burst.
Its performance fully complies with IEC 61000-4-4 Ed.2:2004. Pre-programmed Standard
Test routines and a number of selected User Test routines make the EFT 500N5 an
optimum standalone solution for both testing during development and final testing
of products and sub-assemblies.
Benefits
EFT 500N5 - The Burst/EFT generator that goes beyond specification
The wide ranges offered to adjust the spike frequency and the burst duration are
well-known for many years. Of course, the EFT 500N5 meets the latest waveform requirements
into load at the coaxial 50ohm output as well as at the DUT port in common mode
operation unlike other generators. The EFT 500N5 is the true, fully compliant EFT/Burst
tester.
It is unlike any other ESD generators. Its ergonomic design is recognised to be
more user-friendly. There is no part of dito that hides the discharge tip while
watching the display or operating the dito. You see where you point the tip no matter
how you direct dito to the DUT.
Different models of the standalone EFT 500N5 are avialable. It can be ordered with
a built-in single phase coupler as well as with a built-in three-phase coupler for
rated DUT currents up to 50A.
The EFT 500N5 can also be integrated in a complete test system in combination with
other generators of the EM TEST 500 series and operate via a common coupling/decoupling
network being equipped with the corresponding control interface.
Standards
| EN 61000-4-4 |
IEC 60601-1-2 |
| EN 61000-6-1 |
IEC 61000-4-4 |
| EN 61000-6-2 |
IEC 61326 |
| |
IEC 61850-3 |

|
EFT 500N8
Electrical Fast Transient Generator
Highlights
• Standalone Tester
• 7,000V Burst voltage
• Spike frequency 1MHz
• Built-in 1ph or 3ph coupler
• Standard Test routines
• USB and GPIB interfaces
• Optional iec.control software
•
EFT 500N8 Datasheet
|
Application
EFT 50085 - EFT/Burst tester
The EFT 500N8 is the state-of-the-art EFT/Burst tester with a built-in coupling/decoupling
network for single phase or three-phase mains supply lines and a HV terminal to
connect a capacitive coupling clamp.
The spike frequency can be varied from as low as 100Hz up to 1,000kHz. The EFT 500N8
is capable to generate 10000 spikes per second or up to 150 spikes per burst. Its
performance fully complies with IEC 61000-4-4. Pre-programmed Standard Test routines
and a number of selected User Test routines make the EFT 500N8 an optimum standalone
solution for both testing during development and final testing of products and sub-assemblies.
Benefits
EFT 500N5 - The Burst/EFT generator that goes beyond specification
The wide ranges to adjust the spike frequency and the burst duration are well-known
for many years. Of course, the EFT 500N8 meets the latest waveform requirements
into load at the 50ohm output as well as at the EUT port in common mode operation
unlike other generators. The EFT 500N8 is for sure a fully compliant EFT/Burst tester.
Its increased pulse voltage capability also meets requirements of some special product
family standards and manufacturer requirements, especially household appliances.
Different models of the standalone EFT 500M8 are avialable. It can be ordered with
a built-in single phase coupler as well as with a built-in three-phase coupler for
rated EUT currents up to 32A.
The EFT 500N8 can also be integrated in a complete test system in combination with
other generators of the EM TEST 500 series and operate via a common coupling/decoupling
network being equipped with the corresponding control interface.
Standards
| EN 61000-4-4 |
IEC 61000-4-4 |
| EN 61000-6-1 |
IEC 61326 |
| EN 61000-6-2 |
IEC 61850-3 |

|
UCS 500N5
Ultra-Compact Simulator for Industrial Electronics
Highlights
• Burst module (IEC/EN 61000-4-4) up to 5.5kV
• Surge module (IEC/EN 61000-4-5) up to 5kV
• TSurge module (IEC/EN 61000-4-5); optional
• PowerFail module (IEC/EN 61000-4-11)
• Magnetic field tests with optional accessoires
• Built-in single phase coupler 300V/16A
• Manual operation from front panel
• USB and GPIB-Bus for remote control
• Monitor outputs for peak voltage and peak current
• Fail inputs
• External variac control 0-10Vdc
• Control of external three-phase couplers
• Optional iec.control software
•
UCS 500N5 Datasheet
|
Application
UCS 500N5 - Compact Tester for EFT/Burst, Surge and Power Fail
The UCS 500N5 ultra-compact simulator is the most versatile tester to cover transient
and power fail requirements according to international standards (basic and generic
standards) and product/product family standards. The UCS 500N5 is the most economic
solution for tests during development as well as for full-compliant immunity tests
and CE Marking for single phase DUT with the ability to be extended for testing
three-phase DUTs by means of an automatically controlled external coupling network
up to 100A.
EM TEST supplies a large range of accessories for the various applications such
as magnetic field tests.
Benefits
All in one - All what you need for your tests
The UCS 500N5 includes everything necessary to conduct fully compliant tests. The
power mains supply for the controls and for the DUT is separate to render it more
flexible to use with different DUT supply voltages.
The UCS 500N5 can be operated manually from the front panel or by remote via the
built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence
based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal
measurement and verification. Safety features such as interlock and warning lamp
control are available.
Pre-programmed Standard Test routines allow highest user convenience. Still the
UCS 500N5 offers the Quick Start test routine where parameters can be changed on-line
during the test to evaluate the susceptibility level of an individual DUT.
Standards
| EN 300329 |
EN 50121 |
EN 61000-6-1 |
IEC 61000-4-8 |
| EN 300340 |
EN 55024 |
EN 61000-6-2 |
IEC 61000-4- 9 |
| EN 300342-1 |
EN 61000-4-11 |
FCC 97-270 (part 68) |
IEC 61326 |
| EN 300386 V1.3.2 |
EN 61000-4-29 |
IEC 60255-22-5 |
IEC 61850-3 |
| EN 301489-1 |
EN 61000-4-4 |
IEC 61000-4-11 |
ITU-T K.20 |
| EN 301489-17 |
EN 61000-4-5 |
IEC 61000-4-29 |
ITU-T K.21 |
| EN 301489-24 |
EN 61000-4-8 |
IEC 61000-4-4 |
ITU-T K.41 |
| EN 301489-7 |
EN 61000-4-9 |
IEC 61000-4-5 |
ITU-T K.45 |

|
UCS 500N7
Ultra-Compact Simulator for Industrial Electronics
Highlights
• Ultra-Compact Simulator up to 7.0kV
• Burst module (IEC/EN 61000-4-4)
• Surge module (IEC/EN 61000-4-5)
• PowerFail module (IEC/EN 61000-4-11)
• Ringwave module (IEC/EN 61000-4-12) optional
• Telecom Surge Module (IEC/EN 61000-4-5) optional
• Magnetic field tests with optional accessoires
• Built-in single phase coupler 300V/16A
• USB and GPIB-Bus for remote control
• Manual operation from front panel
• Monitor outputs for peak voltage and peak current
• Fail inputs
• External variac control 0-10Vdc
• Control of external three-phase couplers
• Optional iec.control software
•
UCS 500N7 Datasheet
|
Application
UCS 500N7 - Most Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE
C62.41
The UCS 500N7 ultra-compact simulator is the most versatile tester to cover transient
and power fail requirements according to international standards (basic and generic
standards) and product/ product family standards with voltage capability of up to
7.0 kV. Apart from the IEC 61000-4-5 standard for surge testing it also complies
to ANSI/IEEE C62.41 for surge and ringwave testing.
The UCS 500N7 not only represents the most economic solution for full-compliant
immunity tests and CE Marking but goes far beyond. Having a built-in CDN for single
phase DUTs it can be extended for testing three-phase DUTs by means of an automatically
controlled external coupling network up to 100A.
EM TEST supplies a large range of accessories for the various applications.
Benefits
All in one and more - All what you need for tests up to 7kV
The UCS 500N7 includes everything necessary to conduct fully compliant tests at
levels that go far beyond common test requirements.
Surge can be test up to 7.0kV either according to IEC 61000-4-5 or ANSI/IEEE C62.41.
The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41
and IEC 61000-4-12 for ringwave tests on mains supply lines.
The UCS 500N7 can be operated manually from the front panel or by remote via the
built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence
based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal
measurement and verification. Safety features such as interlock and warning lamp
control are available.
Pre-programmed Standard Test routines allow highest user convenience. Still the
UCS 500N7 offers the Quick Start test routine where parameters can be changed on-line
during the test to evaluate the susceptibility level of an individual DUT, a most
appreciated benefit for tests at development stage.
Standards
| ANSI/IEEE C62.41 |
EN 61000-4-9 |
IEC 61000-4-5 |
IEEE 1547 |
| EN 61000-4-11 |
EN 61543 |
IEC 61000-4-8 |
ITU-T K.20 |
| EN 61000-4-12 |
IEC 60255-22-5 |
IEC 61000-4-9 |
ITU-T K.21 |
| EN 61000-4-29 |
IEC 61000-4-11 |
IEC 61008-1 |
ITU-T K.45 |
| EN 61000-4-4 |
IEC 61000-4-12 |
IEC 61009-1 |
UL 1741 |
| EN 61000-4-5 |
IEC 61000-4-29 |
IEC 61326 |
|
| EN 61000-4-8 |
IEC 61000-4-4 |
IEC 61850-3 |
|

|
UCS 500N7.2
Multifunctional Transient Simulator for Renewable Energy
Highlights
• Ultra-Compact Simulator up to 7.0kV
• Burst module (IEC/EN 61000-4-4)
• Surge module (IEC/EN 61000-4-5)
• PowerFail module (IEC/EN 61000-4-11)
• Telecom Surge Module (IEC/EN 61000-4-5) optional
• Magnetic field tests with optional accessoires
• Built-in single phase coupler 300V/16A
• USB and GPIB-Bus for remote control
• Manual operation from front panel
• Monitor outputs for peak voltage and peak current
• Fail inputs
• External variac control 0-10Vdc
• Control of external three-phase couplers
• Optional iec.control software
•
UCS 500N7.2 Datasheet
|
Application
UCS 500N7.2 - Most Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE
C62.41
The UCS 500N7.2 ultra-compact simulator is the most versatile tester to cover transient
and power fail requirements according to international standards (basic and generic
standards) and product/ product family standards with voltage capability of up to
7.0 kV. Apart from the IEC 61000-4-5 standard for surge testing it also complies
to ANSI/IEEE C62.41 for surge testing. The UCS 500N7.2 not only represents the most
economic solution for full-compliant immunity tests and CE Marking but goes far
beyond. Having a built-in CDN for single phase DUTs it can be extended for testing
three-phase DUTs by means of an automatically controlled external coupling network
up to 100A. EM TEST supplies a large range of accessories for the various applications.
Benefits
All in one and more - All what you need for tests up to 7kV
The UCS 500N7.2 includes everything necessary to conduct fully compliant tests at
levels that go far beyond common test requirements.
Surge can be test up to 7.0kV either according to IEC 61000-4-5 or ANSI/IEEE C62.41.
The UCS 500N7.2 can be operated manually from the front panel or by remote via the
built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence
based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal
measurement and verification. Safety features such as interlock and warning lamp
control are available.
Pre-programmed Standard Test routines allow highest user convenience. Still the
UCS 500N7.2 offers the Quick Start test routine where parameters can be changed
on-line during the test to evaluate the susceptibility level of an individual DUT,
a most appreciated benefit for tests at development stage.
Standards
| ANSI/IEEE C62.41 |
EN 61000-6-1 |
IEC 61000-4-5 |
IEEE 1547 |
| EN 61000-4-11 |
EN 61000-6-2 |
IEC 61000-4-8 |
ITU-T K.20 |
| EN 61000-4-29 |
EN 61543 |
IEC 61000-4-9 |
ITU-T K.21 |
| EN 61000-4-4 |
IEC 60255-22-5 |
IEC 61008-1 |
ITU-T K.45 |
| EN 61000-4-5 |
IEC 61000-4-11 |
IEC 61009-1 |
UL 1741 |
| EN 61000-4-8 |
IEC 61000-4-29 |
IEC 61326 |
|
| EN 61000-4-9 |
IEC 61000-4-4 |
IEC 61850-3 |
|

|
CNI 508N1
Coupling / Decoupling network for shielded high-speed communication lines up to
1GBit/s
Highlights
• Surge test voltage up to 4kV (1.2/50us)
• Ringwave test voltage up to 4kV (0.5us/100kHz)
• Burst test voltage up to 4kV (5/50ns)
• Residual voltage max. 15V at 2kV
• Coupling to shielded lines with up to 4 pairs
• Data transfer up to 1,000MBit/s
• Fully compatible to PoE and PoE+ requirements
• DUT/AE connection via RJ45 male connectors
•
CNI 508N1 Datasheet
|
Application
CNI 508N1 - The unique coupling/decoupling network for shielded high-speed communication
lines
The EM TEST CNI 508N1 is the first coupling/decoupling network available on the
market to couple Surge, Ringwave and EFT/Burst pulses onto shielded high-speed communication
lines with data rates up to 1,000MBit/s in a single unit.
The CNI 508N1 can be used for test voltages of up to 4kV. For tests using the 1.2/50us
surge the CNI 508N1 is based on IEC 61000-4-5(2005).
Additionally, it fully supports PoE and PoE+ standard requirements as per IEEE 802.3af-2003
and IEEE 802.3at-2009.
Benefits
CNI 508N1 - Single box for Surge/Ringwave/Burst coupling onto shielded high-speed
communication lines
The EM TEST CNI 508N1 is a specifically designed and approved coupling/decoupling
network for tests of shielded high-speed communication lines.
By means of the CNI 508N1 Surge pulses (1.2/50us) as per IEC/EN 61000-4-5, Ringwave
(0.5us/100kHz) as per IEC/EN 61000-4-12 and EFT/Burst pulses (5/50ns as per IEC/EN
61000-4-4) can be coupled. A maximum test voltage of 4kV can be applied to the lines
under test.
Its unique design allows data rates of up to 1,000MBit/s to be transmitted without
degradation by the coupling/decoupling network. The CNI 508N1 complies to PoE requirements
as per IEEE 802.3af-2003 as well to P0E+ (PoE plus) requirements as per IEEE 802.3at-2009
with a current of up to 600mA and a power of up to 25.5W.
The integrated decoupling network protects the auxiliary equipment limiting the
residual voltage to max. 15V at 2kV test voltage. The CNI 508N1 is fitted with female
RJ45 connectors to connect telecommunication devices.
Standards
| EN 61000-4-12 |
EN 61000-6-2 |
| EN 61000-4-4 |
IEC 61000-4-12 |
| EN 61000-4-5 |
IEC 61000-4-4 |
| EN 61000-6-1 |
IEC 61000-4-5 |