These are a few of the most popular ECAT configurations. They can be modified by
exchanging or adding the modules listed below.
| Part # |
Description |
Modules Included |
Testing Standard |
| E1000-4-4 |
Fast transient generator to 4.4kV with coupler |
E103, E412 |
IEC 61000-4-4
EN 50082 |
| E1000-4-5-3 |
Combination wave surge to 6.6kv with 3 Phase coupler |
E103, E501, E4554 |
IEC 61000-4-5
ANSI/IEEE C62.41 |
| E1089 |
Bellcore 2x10, 10x360 and 10x1000 telecom surge generator
|
E103, E506-4W E509,E508 |
GR-1089-core |
These plug-ins to the E103 ECAT Controller generate the waveforms defined below.
The first number (1.2) is the rise-time, the second(50) is the fall-time, both in
microseconds. Current is given when defined by the standard.
| Part # |
Description |
Waveform V/I |
Testing Standard |
| E501 |
Combination wave 2&12 ohm |
V=1.2x50 to 6600v I=8x20 to 3300a |
IEC 61000-4-5, ANSI/IEEE C62.41 |
| E502 |
Telecom wave |
V=10x700 or .5x700 to 6000v |
FCC part 68 CCITT K.17 |
| E503 |
100kHz Ring wave |
I=200 or 500 V to 6600v |
IEC 61000-4-12 ANSI/IEEE C62.41 |
| E506-4w |
Bellcore lightening surge |
2x10 to 5000v, 500a |
GR-1089-core |
| E508 |
Bellcore lightening surge |
V=10x360 to 1000v, 100a |
GR-1089-core |
| E509 |
Bellcore lightening surge |
10x1000 to 1500v, 100a |
GR-1089-core |
| E510 |
Combination wave 2&12ohm |
V=1.2x50 to 10kv I=8x20 to 5ka |
UL864 |
| E513 |
Voltage ramp surge |
100v/microsecs, 500v/microsecs, 1kv/microsecs, 5kv/microsecs,
10kv/microsecs to 3000v |
UL864 |
These plug-ins for the E103 Controller generate EFT pulse bursts of 5ms/50ns to
meet national and international standards, including IEC 1000-4-4. Some include
coupler/filters.
| Part # |
Description |
Coupler/Filter |
Max Voltage |
| E411 |
EFT generator, 50 ohm output imped. |
not included |
4.4kV |
| E412 |
EFT generator, 50 ohm output imped. |
250v/16a single phase |
4.4kV |
| E421 |
EFT generator, 50 ohm output imped. |
not included |
8kV |
| E424 |
EFT generator, 50 ohm output imped. |
480v/32a three phase |
4.4kV |
These modules are required to couple the surge onto the power line. The E551 can
be used only with Series 500 modules; the rest with both surge and EFT modules.
All include built-in voltage and current monitors and coupling modes under complete
software control.
| Part # |
Description |
Max. EUT voltage/current |
| E551 |
Sure Coupler/Filter - single phase |
250V/16A |
| E4552 |
E4552 plus HV option |
480V/32A |
| E4554 |
Surge and EFT coupler - three phase |
480V/32A |
| E4554-HV |
Surge and EFT coupler - three phase |
600V/32A |
| Part # |
Description |
| 103 |
Controller for ECAT system with front panel and software operation
|
| EP62 |
Plug-in provides swells, dips and interrupts (PQF) on power
mains per IEC 1000-4-11 |
| CCL-4/s |
Capactive coupling clamp for testing I/O and data lines per
IEC 1000-4-11 |